4.8 Sanitation Technical conditions
4.8.1 Remediation Goals
Remediation objective historical soil contamination exists under the
soil decree to prevent the soil poses a risk or may present to
report: First phased BSP, BP Antwerp, Benzineweg 11, 2020
Antwerp
46,326,785-R150713-V01-BSP_BP ANTWERPEN_DRAFT.DOCX
Project Nr. / Date: 46326785.685 / 07.13.2015
30
adverse effects on man or the environment by making use of the best available
. Techniques not entailing excessive costs entail (BATNEEC)
The four responsible for cleaning contaminants should be cleaned up because of pure product
exist, for which a policy-based remediation obligation. If remediation objective is
therefore provided to remove the pure product.
4.8.2 Activities that can hinder the remediation
, the site is in full activity. Substantial remediation techniques activities were partially or
hinder full.
The location of the four floating layers is shown on the figures in Appendix H. Pollution 1
is located more than 90% below the northern tank park. Pollution 3
is located entirely within the business path to the northern tank farm. 4 pollution is
almost completely under the water treatment plant in the southern part of the terrain. Contamination 6 is almost
completely under the tank farm that is part of the lubricant factory on the southern
part of the terrain. These structures can not be removed without the business
to shut down a long time.
4.8.3 Future plans: construction projects, specific activities, development plans
BP has no plans to discontinue operations at the site in Antwerp. The current
environmental license runs until 2016, but will be renewed, the current concession
runs until 2035.
4.8.4 Existing structures that may or may not be removed
, see section 4.8.2
4.8.5 Stability Measures and settlement calculations
Not applicable
4.8. 6 presence basements and depth
There are no basements exist.
4.8.7 Sewage, cables, conduits
within the core zones are product lines and drainage pipes present.
4.8.8 Setting Sensitivity to noise, odor emissions
in the immediate vicinity there are no neighbors. The site is located in an
industrial area, making certain noise levels are permissible. A possible reorganization will
probably cause additional noise.
The remediate pollution consists partly of volatile components. Where necessary,
specific measures should be considered to comply with the applicable
air emission standards.
4.8.9 Proximity surface water discharge points in the area
Report: First phased BSP, BP Antwerp, Benzineweg 11, 2020
Antwerp
46,326,785-R150713-V01-BSP_BP ANTWERPEN_DRAFT. DOCX
Project Nr. / Date: 46326785.685 / 07.13.2015
31
De Schelde adjacent to the northern side of the site. The effluent water from the
water treatment plant which is present on the Site, is discharged into a stream southeast
of the Site. In a possible reorganization of purified water can be at the same point of discharge
discharged.
4.8.10 Site accessibility
The site is accessible for trucks and cars through the Benzineweg. Also,
if transportation is arranged by boats on the river Scheldt.
4.8.11 Groundwater Winningen in the area and any foreseeable nuisance
within a radius of 1 km are no according to the website DOV Flanders
groundwater. It is therefore not expected to have an impact on a
possible reorganization.
4.8.12 Other groundwater contamination in the area or the location itself
around the site and there were still other risk activities related
contaminants may have caused the surface. In passing to a
possible reorganization whereby bemaald should be, should soil surveys from neighboring
plots are consulted.
4.8.13 Biological degradation parameters
No data are available.
Given the remediate contaminants consist of pure product, biological degradation and
remediation technique is not an option .
4.8.14 cleanability of the ground
view of the soil is polluted only with mineral oil products it is assumed that from
these biological, physico-chemically or thermally can be cleaned, depending on the
concentration and the existing mineral oil fractions. Any removed floating layer may separately
be disposed of, but likely needs to be combusted.
4.8.15 Parameters for groundwater extraction and groundwater treatment
A active abstraction of the groundwater is currently impossible, since this could
lead to inadmissible subsidence of the existing old tanks.
If, however, other waste water streams should be generated